Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC (CROSBI ID 200645)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Chatrchyan, S. ; ... ; Godinović, Nikola ; Lelas, Damir ; Pleština, Roko ; Polić, Dunja ; Puljak, Ivica ; Antunović, Željko ; Kovač, Marko ; Brigljević, Vuko et al. The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC // Journal of Instrumentation, 8 (2013), P11002-1-P11002-102. doi: 10.1088/1748-0221/8/11/P11002

Podaci o odgovornosti

Chatrchyan, S. ; ... ; Godinović, Nikola ; Lelas, Damir ; Pleština, Roko ; Polić, Dunja ; Puljak, Ivica ; Antunović, Željko ; Kovač, Marko ; Brigljević, Vuko ; Đurić, Senka ; Kadija, Krešo ; Luetić, Jelena ; Morović, Srećko ; Mekterović, Darko ; ... ; Swanson, J.

engleski

The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC

The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton--proton collision data at sqrt(s) = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40 inverse picobarns. The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial resolution per chamber was 80-120 micrometers in the DTs, 40-150 micrometers in the CSCs, and 0.8-1.2 centimeters in the RPCs. The time resolution achievable was 3 ns or better per chamber for all 3 systems. The efficiency for reconstructing hits and track segments originating from muons traversing the muon chambers was in the range 95-98%. The CSC and DT systems provided muon track segments for the CMS trigger with over 96% efficiency, and identified the correct triggering bunch crossing in over 99.5% of such events. The measured performance is well reproduced by Monte Carlo simulation of the muon system down to the level of individual channel response. The results confirm the high efficiency of the muon system, the robustness of the design against hardware failures, and its effectiveness in the discrimination of backgrounds.

Muon spectrometers; Particle tracking detectors; Particle tracking detectors (Gaseous detectors)

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

8

2013.

P11002-1-P11002-102

objavljeno

1748-0221

10.1088/1748-0221/8/11/P11002

Povezanost rada

Fizika

Poveznice
Indeksiranost