Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The electrocoagulation/advanced oxidation treatment of the well water from Županja (CROSBI ID 200450)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Oreščanin, Višnja ; Kollar, Robert ; Vratarić, Dražen ; Nađ, Karlo ; Medunić, Gordana ; Lončar, Goran ; Halkijević, Ivan ; Kuspilić, Marin The electrocoagulation/advanced oxidation treatment of the well water from Županja // Glasnik hemičara, tehnologa i ekologa Republike Srpske, 1 (2013), 37-41. doi: 10.7251/GHTE1309037O

Podaci o odgovornosti

Oreščanin, Višnja ; Kollar, Robert ; Vratarić, Dražen ; Nađ, Karlo ; Medunić, Gordana ; Lončar, Goran ; Halkijević, Ivan ; Kuspilić, Marin

engleski

The electrocoagulation/advanced oxidation treatment of the well water from Županja

The purpose of this work was development and application of the purification system suitable for the treatment of groundwater used for human consumption as well as watering of the plants in the system for the hydroponic cultivation of tomatoes. For that purpose the well water from the 60 m deep water layer situated near the city of upanja (Eastern Croatia) was processed. Most of the measured parameters exceeded upper permissible limit (UPL) for drinking water. The concentrations of the parameters color, turbidity, iron, manganese, arsenic, phosphates, chemical oxygen demand and ammonia were as follows 292±20 mg/PtCo, 21±5 NTU, 1.72±0.34 mg/L, 0.075±0.014 mg/L, 0.074±0.011 mg/L, 10.4±1.7 mg/L, 37±1 mg/L and 1.2±0.1 mg/L, respectively. Due to the complex composition of the treated water, the purification system required the combination of electrochemical treatment, using iron and aluminum electrode plates with simultaneous ozonation followed by post treatment with hydrogen peroxide and ozone. The electrocoagulation/ozonation approach was used for the removal of heavy metals, color, turbidity, phosphates and partially organic matter while the rest of the organic contaminants and ammonia were removed by the treatment with hydrogen peroxide and ozone. Following the combined electrochemical treatment and post treatment with hydrogen peroxide and ozone all measured parameters in the treated water were in agreement with regulated values. The combined treatment resulted in total removal of arsenic, color, turbidity, ammonia and organic contaminants while the removal of other parameters of interest was up to 97.98%.

Heavy metals ; arsenic ; ammonia ; electrocoagulation ; ozonation ; iron anode ; aluminum anode ; hydrogen peroxide

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

1

2013.

37-41

objavljeno

1840-054X

2232-755X

10.7251/GHTE1309037O

Povezanost rada

Kemija

Poveznice