Two cases of lethal complications following ultrasound - guided percutaneous fine-needle biopsy of the liver (CROSBI ID 79061)

Prilog u časopisu | ostalo

Drinković, Ivo ; Brkljačić, B. Two cases of lethal complications following ultrasound - guided percutaneous fine-needle biopsy of the liver // Cardiovascular and interventional radiology, 19 (1996), 5; 360-363-x

Podaci o odgovornosti

Drinković, Ivo ; Brkljačić, B.

engleski

Two cases of lethal complications following ultrasound - guided percutaneous fine-needle biopsy of the liver

Two cases with lethal complications are reported among 1750 ultrasound (US)-guided percutaneous fine-needle liver biopsies performed in our department. The first patient had angiosarcoma of the liver which was not suspected after computed tomography (CT) and US studies had been performed. The other patient had hepatocellular carcinoma in advanced hepatic cirrhosis. Death was due to bleeding in both cases. Pre-procedure laboratory tests did not reveal the existence of major bleeding disorders in either case. Normal liver tissue was interposed in the needle track between the liver capsule and the lesions which were targeted.

lethal complications; ultrasound; percutaneous fine-needle biopsy; liver

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

19 (5)

1996.

360-363-x

objavljeno

0174-1551

Povezanost rada

Kliničke medicinske znanosti

Indeksiranost