Properties of Printer Calibration Targets


Donevski, Davor; Milčić, Diana; Borković, Jakov
Properties of Printer Calibration Targets // The International Circle of Educational Institutes for Graphic Arts: Technology and Management, 6 (2013), 70-79 (podatak o recenziji nije dostupan, članak, znanstveni)


Naslov
Properties of Printer Calibration Targets

Autori
Donevski, Davor ; Milčić, Diana ; Borković, Jakov

Izvornik
The International Circle of Educational Institutes for Graphic Arts: Technology and Management (1868-0712) 6 (2013); 70-79

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
G7; printer calibration; calibration target

Sažetak
Printer calibration targets can differ with respect to aims of the calibration. In this study, GrayFinder target as described in the G7 Specification was modified and tested on an RGB printer. It was inspected whether it is beneficial to vary all three device channels instead of keeping one channel constant. The relations between input value RGB ranges and CIE L*a*b* domain were also monitored. It was found that varying all channels can lead to improvement by widening L*a*b* domain, with the cost of increasing the target size.

Izvorni jezik
Engleski

Znanstvena područja
Grafička tehnologija



POVEZANOST RADA


Projekt / tema
128-1281955-1951 - Standardizacija ekološki prihvatljivih procesa grafičkih komunikacija (Diana Milčić, )

Ustanove