Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Detection of factor V Leiden by PCR-SSCP using precast Elchrom Scientific GMATM gels (CROSBI ID 480088)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Ivanišević, Ana-Maria ; Štefanović, Mario ; Topić, Elizabeta Detection of factor V Leiden by PCR-SSCP using precast Elchrom Scientific GMATM gels // Clinical Chemistry, 52nd AACC Annual Meeting, Abstracts of scientific posters / Bruns, David E (ur.). Washington (MD): American Association for Clinical Chemistry (AACC), 2000. str. A134-x

Podaci o odgovornosti

Ivanišević, Ana-Maria ; Štefanović, Mario ; Topić, Elizabeta

engleski

Detection of factor V Leiden by PCR-SSCP using precast Elchrom Scientific GMATM gels

A point mutation in the coagulation Factor V gene (FV:R506Q) called Factor V Leiden is the most common cause of thrombophilia. Since the prevalence of Factor V Leiden in normal population is high, it would be reasonable to perform a simple and cost-effective method for screening the genetic abnormality in population at risk. Here we present a new simple, reproducible and cheap PCR-SSCP method that allows us to identify the carriers of Factor V mutation. Single-Strand Conformation Polymorphism (SSCP) is a mutation detection method based on changes in the secondary structure within a defined ssDNA fragment. The aim of this study was to optimize PCR-SSCP method for detection of Factor V Leiden mutation using the precast GMA™ gels in the Elchrom Scientific SEA 2000 apparatus. We performed PCR-SSCP analysis on 50 whole blood DNA samples previously genotyped by PCR-RFLP method. Exon X of Factor V was amplified using previously described primers and denatured at 95°C during 5 minutes. Denatured PCR products were loaded and run overnight on precast GMA gels in SEA 2000 electrophoresis apparatus. Gels were stained for 30 min with SYBR Gold nucleic stain, destained for 40 min in double distilled water and photographed at 254 nm with Polaroid 667 film. We observed reproducible and uniform band patterns for mutant and wild type variants of Factor V. Our PCR-SSCP results were verified using the restriction pattern after Mnl I digestion of the same PCR product. Results always matched completely, the concordance between both methods was 100 %. Technique has shown to be highly reproducible because of high performance characteristics of GMA gels and constant temperature maintenance by Elchrom Scientific SEA 2000 apparatus. In conclusion, described PCR-SSCP procedure is reliable, time saving and cost effective and should therefore be useful in the routine detection of Factor V Leiden.

factor V Leiden; PCR-SSCP

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

A134-x.

2000.

objavljeno

Podaci o matičnoj publikaciji

Clinical Chemistry, 52nd AACC Annual Meeting, Abstracts of scientific posters

Bruns, David E

Washington (MD): American Association for Clinical Chemistry (AACC)

Podaci o skupu

52nd AACC Annual Meeting

poster

23.07.2000-27.07.2000

San Francisco (CA), Sjedinjene Američke Države

Povezanost rada

Temeljne medicinske znanosti