Comparation of conventional tube method with gel column method for anti A/B titration (CROSBI ID 602325)
Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija
Podaci o odgovornosti
Hećimović, Ana ; Hundrić Hašpl, Željka ; Juraković Lončar, Nina ; Kruhonja Galić, Zrinka ; Jagnjić, Sandra ; Balija, Melita ; Jukić, Irena
engleski
Comparation of conventional tube method with gel column method for anti A/B titration
Background: The titer of isohemagglutinins in patient is a very important factor for success of incompatible organ transplantation. The goal of isohemagglutinin titer to prevent rejection is variable across transplantation centers, depending of the method, ranging from ≤ 1:2 to ≤ 1:32 before transplantation. So, screening for high titer of antibodies could reduce the risk of adverse reaction. There are several options for the measurement of isohemagglutinin titer. Conventional tube method has some disadvantages because technical variables greatly affect the results. Gel column method is technically much simpler and test results are more balanced. Aim: The aim of this study is determination of differences in test sensitivity of both methods using regression analysis
titer of isohemagglutinins; comparation of methods
DOI: 10.1111/vox.12048
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
203-203.
2013.
nije evidentirano
objavljeno
Podaci o matičnoj publikaciji
Vox sanguinis
Devine, D.
Oxford: Blackwell Publishing
0042-9007
Podaci o skupu
Regional Congress of the International Society of Blood Transfusion (23 ; 2013)
poster
02.06.2013-05.06.2013
Amsterdam, Nizozemska
Povezanost rada
Temeljne medicinske znanosti