Primjena Au/CA/NTA senzora za određivanje olova pomoću voltametrije s katodnim “strippingom” (CROSBI ID 601667)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | domaća recenzija

Palčić, Marina ; Kereković, Irena ; Milardović, Stjepan ; Grabarić, Zorana ; Kapor, Frankica Primjena Au/CA/NTA senzora za određivanje olova pomoću voltametrije s katodnim “strippingom” // XXIII. hrvatski skup kemičara i kemijskih inženjera : knjiga sažetaka = XXIIIth Croatian Meeting of Chemists and Chemical Engineers : book of abstracts / Hadžiev, Andrea ; Blažeković, Zdenko (ur.). Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2013. str. 125-125

Podaci o odgovornosti

Palčić, Marina ; Kereković, Irena ; Milardović, Stjepan ; Grabarić, Zorana ; Kapor, Frankica

hrvatski

Primjena Au/CA/NTA senzora za određivanje olova pomoću voltametrije s katodnim “strippingom”

A self assembled monolayer (SAM) of cysteamine (CA) was prepared on the surface of gold disc electrode and further modified with nitrilotriacetic acid (NTA). Characterization of prepared Au/CA/NTA electrode was done with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in the presence of potassium hexacyanoferrate(II)/(III). Thus prepared electrode was tested for determination of lead. The binding of Pb2+ onto the modified electrode was successfully performed in the wide range of tested concentrations. The response of modified electrode to Pb2+ concentration was measured by cathodic stripping voltammetry. Under the optimized working conditions (accumulation time, pH for lead accumulation, and pH for lead stripping), the dependence of the stripping peak current response on concentration of Pb2+ was linear in the range of 0.001 – 10 µM with a correlation coefficient of 0.9839. The interference of Co2+, Ni2+ Mg2+, Mn2+ and Ca2+ was significantly reduced in boric buffer pH=7. Lead determination in potable and thermal water samples confirmed practical application of prepared sensor.

samoformirajući sloj; senzor; voltametrija s otapanjem; olovo

nije evidentirano

engleski

Application of Au/CA/NTA Sensor for Lead Determination by Cathodic Stripping Voltammetry

nije evidentirano

self assembled monolayer; sensor; cathodic stripping voltammetry; lead

nije evidentirano

Podaci o prilogu

125-125.

2013.

objavljeno

Podaci o matičnoj publikaciji

XXIII. hrvatski skup kemičara i kemijskih inženjera : knjiga sažetaka = XXIIIth Croatian Meeting of Chemists and Chemical Engineers : book of abstracts

Hadžiev, Andrea ; Blažeković, Zdenko

Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI)

978-953-6894-50-5

Podaci o skupu

Hrvatski skup kemičara i kemijskih inženjera (23 ; 2013)

poster

21.04.2013-24.04.2013

Osijek, Hrvatska

Povezanost rada

Kemija