Testing of cracked concrete slabs (CROSBI ID 600852)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Bartolac, Marko ; Rak, Mladenko ; Frančić, Marina
engleski
Testing of cracked concrete slabs
This paper presents testing of cracked concrete slabs in a three-storey underground garage in one commercial building in Zagreb. Axial dimensions of the slabs supported by rectangular columns (1, 2 m x 0, 6 m) are 8, 0 m x 8, 0 m and their thickness is from 28 cm to 32 cm, depending on the slab's position. Most of the cracks appeared soon after construction in 2007. and since then they present a constant durability problem (corrosion of reinforcement bars and, subsequently, deterioration of concrete protection layer). Testing of the slabs was needed in order to check their load bearing capacity before making decisions about their sanation. Detailed static and dynamic tests were conducted on both cracked and undamaged slabs (in order to gain reference values).
concrete; slab; crack; testing
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
2013.
objavljeno
Podaci o matičnoj publikaciji
Proceedings of 30th Danubia-Adria Symposium on Advances in Experimental Mechanics
Alfirević, Ivo ; Semenski, Damir
Zagreb: Hrvatsko društvo za mehaniku (HDM)
978-953-7539-17-7
Podaci o skupu
30th Danubia Adria Symposium on Advances in Experimental Mechanics
poster
25.09.2013-28.09.2013
Primošten, Hrvatska