Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The development of electrochemical methods for determining nanoparticles in the environment. Part II : chronoamperometric study of FeS in sodium chloride solutions (CROSBI ID 195883)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bura-Nakić, Elvira ; Marguš, Marija ; Milanović, Ivana ; Jurašin, Darija ; Ciglenečki-Jušić, Irena The development of electrochemical methods for determining nanoparticles in the environment. Part II : chronoamperometric study of FeS in sodium chloride solutions // Environmental chemistry, 11 (2013), 2; 187-195. doi: 10.1071/EN13090

Podaci o odgovornosti

Bura-Nakić, Elvira ; Marguš, Marija ; Milanović, Ivana ; Jurašin, Darija ; Ciglenečki-Jušić, Irena

engleski

The development of electrochemical methods for determining nanoparticles in the environment. Part II : chronoamperometric study of FeS in sodium chloride solutions

The interactions of FeS nanoparticles (NPs) with a hanging mercury drop electrode in NaCl solutions were monitored by chronoamperometric measurements. Collisions of FeS NPs with the mercury surface were studied in a wide range of electrode potentials (between 0 and –1.9 V vs. Ag/AgCl). Faradaic impact transients were recorded only at the negative potentials (between –1.5 V and –1.9 V). It was shown that the mercury electrode surface modified with a FeS adlayer catalyzes sodium reduction by shifting the potentials of this process to more positive values. This catalytic process together with possible hydrogen evolution is assumed to be the physicochemical basis for the determination of FeS NPs. Chronoamperometric measurements at the electrode potential of –1.9 V showed that the reduction processes of sodium and/or hydrogen on FeS NPs upon collision are the main cause of sharp reduction current transients. At sufficiently positive electrode potentials (around –1.5 V) the colliding FeS NPs would not be immediately repelled ; instead they stayed stuck at the mercury surface, causing “staircase-like” chronoamperometric signals. It appears that recorded reduction current transients are carrying FeS NPs size information, what is consistent with parallel dynamic light scattering (DLS) measurements.

chronoamperometry; collision; impact transients; FeS nanoparticles; Hg electrode

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

11 (2)

2013.

187-195

objavljeno

1448-2517

10.1071/EN13090

Povezanost rada

Geologija

Poveznice
Indeksiranost