Correcting rms value of a sine waveform sampled due limited number of periods and determinate aperture time on DMM (CROSBI ID 599176)
Prilog sa skupa u zborniku | izvorni znanstveni rad
Podaci o odgovornosti
Ferković, Kristina ; Hegeduš, Hrvoje
engleski
Correcting rms value of a sine waveform sampled due limited number of periods and determinate aperture time on DMM
Sampling of a sine waveform with high-resolution integrating DMM with the input parameters, such as aperture, sampling and measurement time, number of bursts, the number of harmonics, expected RMS and measured frequency of a signal can be accurate to 5 ppm. The precision of a measured frequency can highly influence on sampling parameters. The amplitude of expected RMS behaves as sinc function due change of an aperture time. Still the error exists. The alternative method for correction of a root-mean-square value of a measured sine signal due impact of aperture time is presented.
Digital Multimeter; Root Mean Square Error; Sampling; Aperture time; Number of Samples
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
130-137.
2013.
objavljeno
Podaci o matičnoj publikaciji
Abstracts collection on new challenges in the European Area: International Baku Forum of young scientists.
Baku:
Podaci o skupu
Baku Forum
pozvano predavanje
20.05.2013-25.05.2013
Baku, Azerbajdžan