Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

A stop-flow microperfusion technique for rapid determination of HCO3-absorption/H+ secretion by isolated renal tubules (CROSBI ID 91535)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Muller-Berger, S. ; Samaržija, Ita ; Kunimi, M. ; Yamada, H. ; Fromter, E. ; Seki, G. A stop-flow microperfusion technique for rapid determination of HCO3-absorption/H+ secretion by isolated renal tubules // Pflügers Archiv, 439 (1999), 1; 208-215. doi: 10.1007/s004249900171

Podaci o odgovornosti

Muller-Berger, S. ; Samaržija, Ita ; Kunimi, M. ; Yamada, H. ; Fromter, E. ; Seki, G.

engleski

A stop-flow microperfusion technique for rapid determination of HCO3-absorption/H+ secretion by isolated renal tubules

In the present experiments on microdissected tubules of rabbit kidney we present a refined stop-flow method for determining the rate of HCOy~ absorption (JHco3) or H+ secretion (JH) that can be applied to isolated microperfused tubules. Using the pH-sensitive indicator dye BCECF (2’ , 7’ -bis (7-carboxyethyl]-5 [6)-car- boxyfluorescein) the luminal perfusate pH is continuously measured with a microspectrofiuorometric set-up, and the pH change following a sudden stop of perfusion is analysed. Because the tubules partially collapse after stop-flow the calculation of fluxes requires a correction for volume loss. This is achieved by referring all fluxes to the remaining luminal volume, which can be estimated from the decay of the 440 nm reference fluorescence. During perfusion of the lumen with pure HCO3- Ringer solution, and of the bath with the same solution but containing 5.5 mmol/1 u-glucose as metabolic substrate, JHCO3 averaged 4.4ą0.2 pmol cm’s’ (n=40) and 13.4ą0.8 pmol.cm’s’ (n=5) in proximal straight tubules (PST) and in proximal convoluted tubules respectively. These values agree very well with data obtained in other laboratories with the picapnotherm technique. The present method has the advantage of requiring fewer micromanipulations and a shorter measuring time, thus allowing regulatory changes in JHCO3 to be analysed. Moreover it does not involve measurements of radioactivity, and it also allows JH to he measured in HCO3 free solutions which in PST averaged 0.9 pmol.cm’.s’ (n=8) in the present experiments.

BCECF ; H+secretion ; HCO3-absorption ; isolated renal proximal tubule ; luminal pH

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

439 (1)

1999.

208-215

objavljeno

0031-6768

1432-2013

10.1007/s004249900171

Povezanost rada

Temeljne medicinske znanosti

Poveznice
Indeksiranost