Echocardiography in detecting implantable cardioverter defibrillator lead endocarditis: Case report (CROSBI ID 193568)
Prilog u časopisu | stručni rad
Podaci o odgovornosti
Vincelj, Josip ; Baršić, Bruno ; Rudež, Igor ; Unić, Daniel ; Udovičić, Mario
engleski
Echocardiography in detecting implantable cardioverter defibrillator lead endocarditis: Case report
Lead endocarditis is an infrequent but potentially lethal complication of implantable cardioverter defibrillator (ICD) implantation. We report a case of a 53-year-old man with ICD who admitted to our hospital because of fever, chills, shivering, headache and malaise. TTE detected a structure highly suspect of vegetation located on the ICD lead. TEE showed a 20x12 mm mobile vegetation attached to the ICD lead in the right atrium. The infection was caused by methicillin-resistant Staphylococcus epidermidis (MRSE), which was isolated from blood cultures. Treatment consisted of surgical removal of the ICD lead and placement of new epicardial ICD leads. Three years afterwards, the patient remained asymptomatic. To our knowledge, this is the first such case reported from Croatia.
resistant Staphylococcus epidermidis; Echocardiography