Intercomparison of environmental dosemeters using various TL materials and dosimetry systems (CROSBI ID 596156)

Prilog sa skupa u zborniku | izvorni znanstveni rad

Zorko, Benjamin ; Knežević, Željka ; Črnič, Boštjan ; Majer, Marija ; Gobec, Sandi ; Ranogajec-Komor, Mária Intercomparison of environmental dosemeters using various TL materials and dosimetry systems // Zbornik radova 9.Simpozija Hrvatskog društva za zaštitu od zracenja / Knežević, Željka ; Majer, Marija ; Krajcar Bronić, Ines (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2013. str. 127-132

Podaci o odgovornosti

Zorko, Benjamin ; Knežević, Željka ; Črnič, Boštjan ; Majer, Marija ; Gobec, Sandi ; Ranogajec-Komor, Mária

engleski

Intercomparison of environmental dosemeters using various TL materials and dosimetry systems

The aim of the present work was to compare the ambient dose equivalent (H*(10)) values determined at 20 sites around NPP Krško, using different thermoluminescence (TL) materials and various dosimetry systems. The H*(10) was measured by the CaF2:Mn (TLD-400) provided by the Jožef Stefan Institute (JSI) Ljubljana, Slovenia. These dosemeters were deployed in the environment in plastic bags and suspended inside the plastic bottles. On the other hand the Ruđer Bošković Institute (RBI), Zagreb, Croatia applied LiF:Mg, Cu, P (TLD-100H), CaF2:Mn, Al2O3:C TL detectors and radiophotoluminescence (RPL) glass dosemeters type SG1. They were placed at the same locations in as much as possible same conditions as JSI detectors. According to the protocol established for this intercomparison, the control and transport detectors (not deployed in the environment) were held in dark storage containers and used to determine the background radiation. The TL responses were corrected for individual sensitivity of the TL detectors which is an important factor after the calibration irradiations. The calibration irradiations were performed by 137Cs sources provided in Secondary Standard Dosimetry Laboratory facilities at the JSI and RBI. The results obtained by different TL materials and different dosimetry systems show interesting features especially concerning local environmental peculiarities. The H*(10) obtained by the dosemeters of various types deployed in the countryside fluctuate less than 10 %. The outcome should emphasize also in the manner that the results obtained and reported in the intercomparison are traceable to the primary standards.

Environmental dosemeters; TL materials; RPL; intercomparison

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

127-132.

2013.

objavljeno

Podaci o matičnoj publikaciji

Zbornik radova 9.Simpozija Hrvatskog društva za zaštitu od zracenja

Knežević, Željka ; Majer, Marija ; Krajcar Bronić, Ines

Zagreb: Hrvatsko društvo za zaštitu od zračenja

978-953-96133-8-7

Podaci o skupu

9. SIMPOZIJ HRVATSKOG DRUŠTVA ZA ZAŠTITU OD ZRAČENJA

predavanje

10.04.2013-12.04.2013

Krk, Hrvatska