Evaluation of the fully automated ACS:180 plus chemiluminiscence system (CROSBI ID 464717)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Vrkić, Nada ; Ružić, Dragica ; Topić, Elizabeta ; Petek, Marijan ; Petek, Iva ; Tarle, Marko ; Lukinac, Ljerka Evaluation of the fully automated ACS:180 plus chemiluminiscence system // The official publication of Medlab 97 : Abstracts / Vonderschmitt, Dieter J. (ur.). Basel: Degra AG, Werbung/Marketing-Services, Rotkreuz, 1997. str. 233-233-x

Podaci o odgovornosti

Vrkić, Nada ; Ružić, Dragica ; Topić, Elizabeta ; Petek, Marijan ; Petek, Iva ; Tarle, Marko ; Lukinac, Ljerka

engleski

Evaluation of the fully automated ACS:180 plus chemiluminiscence system

The ACS:180 plus system is an automated chemiluminescence system that measures the amount of light emitted during a chemiluminescent reaction involving the ACS assays, using acridinium ester as the label and paramagnetic particles for the solid phase. Hormones (T3, T4, FT3, FT4, TSH, LH, FSH, prolactin, total HCG, estradiol, progesterone, testosterone, cortisol), drugs (digoxin, vancomycin, phenobarbital, theophylline, phenytoin, gentamycin), tumor markers (CEA, AFP, ferritin, PSA), IgE and vitamin B12 were evaluated according to the guidelines of ECCLS and of SFBC. The reagents and test definitions were supplied by Ciba Corning. Analytical evaluation was done by measuring intra- and inter-assay precision, accuracy, carry-over, linearity and comparison. Comparison study was made with RIA, IRMA and DELFIA methods. Intra-assay CV for hormones, drugs, tumor markers, IgE and vitamin B12 was 0.42%-3.56%, 0.38%-2.87%, 1.34%-4.81%, 2.45%-3.17% and 2.56%-4.00%, respectively. Inter-assay CV (within 10 days) for hormones, drugs, tumor markers, IgE and vitamin B12 was 1.99%-5.66%, 2.34%-5.45%, 3.43%-7.21%, 4.12%-5.77% and 4.11%-4.99% respectively. Sample to sample carry-over was negligible(K less than 0.01%). Study on dilutions showed good linearity for the analytical range. Results of the comparison study showed satisfactory correlation coefficients for hormones r=0.840 to 0.996, for drugs r=0.993 to 0.998, for tumor markers r=0.961 to 1.000, and for IgE r=0.978. The evaluation showed the ACS:180 PLUS to be a precise, accurate and reliable instrument in laboratory routine.

ACS:180 plus system; chemiluminescence; comparison study; RIA; IRMA; DELFIA

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

233-233-x.

1997.

objavljeno

Podaci o matičnoj publikaciji

The official publication of Medlab 97 : Abstracts

Vonderschmitt, Dieter J.

Basel: Degra AG, Werbung/Marketing-Services, Rotkreuz

Podaci o skupu

12th IFCC Eueopean Congress of Clinical Chemistry

poster

17.08.1997-22.08.1997

Basel, Švicarska

Povezanost rada

Temeljne medicinske znanosti, Farmacija