Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Scaled Experimental Verification of Single-Well Induction Conductivity Measurement Through Nonmagnetic Casing (CROSBI ID 190670)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Vasić, Darko ; Bilas, Vedran ; Peyton, Anthony J. Scaled Experimental Verification of Single-Well Induction Conductivity Measurement Through Nonmagnetic Casing // IEEE transactions on instrumentation and measurement, 62 (2013), 5; 1199-1206. doi: 10.1109/TIM.2013.2238031

Podaci o odgovornosti

Vasić, Darko ; Bilas, Vedran ; Peyton, Anthony J.

engleski

Scaled Experimental Verification of Single-Well Induction Conductivity Measurement Through Nonmagnetic Casing

The electromagnetic induction measurement of dimensions, integrity, or material properties of conductive objects is especially challenging in the case when the electrical conductivity of these objects spans five to seven orders of magnitude. Such an application is the conductivity measurement of the surrounding rocks from within a metal casing of an oil well. The rock conductivity measurement is required in order to determine and revaluate hydrocarbon-bearing layers. We present the first experimental verification of the single-well through-casing induction measurement on a scaled laboratory model of a borehole lined with a stainless steel or copper casing surrounded with a low-conductive medium. The measurements are in the frequency range of 2–16 kHz (10–80 Hz in case of the actual borehole). We explain the theoretical background of the method, describe the scaled model and experimental procedure, and discuss the experimental results. The measurement results are in agreement with the theoretical predictions (relative error less than 15%), and the equivalence of the results for the steel and copper casings (average relative discrepancy less than 10%) corroborates that the rock conductivity measurement can be corrected for variations in the casing properties (dimensions, electrical conductivity, and magnetic permeability).

cased well; conductivity measurement; eddy currents; electromagnetic induction; rocks; scaled modeling; well logging

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

62 (5)

2013.

1199-1206

objavljeno

0018-9456

10.1109/TIM.2013.2238031

Povezanost rada

Elektrotehnika

Poveznice
Indeksiranost