Investigation of Dry and Combined Method Used for Measurement and Maintenance Control of Liquid Storage Tank Capacity (CROSBI ID 593613)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Uravić, Valter ; Car, Zlatan ; Kršulja, Marko ; Šikulec, Leon ; Radelja, Hrvoje Investigation of Dry and Combined Method Used for Measurement and Maintenance Control of Liquid Storage Tank Capacity // Proceedings PLIN2012 / Raos, Pero (ur.). Slavonski Brod: Strojarski fakultet Sveučilišta u Slavonskom Brodu, 2012. str. 5-1-5-11

Podaci o odgovornosti

Uravić, Valter ; Car, Zlatan ; Kršulja, Marko ; Šikulec, Leon ; Radelja, Hrvoje

engleski

Investigation of Dry and Combined Method Used for Measurement and Maintenance Control of Liquid Storage Tank Capacity

This paper presents an investigation of liquid storage tanks capacity. A measurement method used in maintenance is shown for liquid tanks manufactured by DIN6602 standard. Measurements were conducted with calibrated measurement etalon AM ET 1500 Litres. Relevant data was analysed with software TankCalc and the results of dry and combined (wet) measurement method were compared. The process and regulations for necessary calculations are shown and the results are shown graphically for better understanding. A method for calculation under the influence of inclination is shown and recommendations for error reduction are given. The emphasis is given to differentiate the advantages of geometrical towards the advantages of combined measurement method. Specifically, these two methods are most wanted by the owner of the liquid tanks and this investigation was to explore what can be expected from each method with respect to errors. Also the paper points out the importance of proper design of liquid storage tanks and an investigation of storage tank for petrol E 95 with volume 50 m3 is shown. The importance of maintenance and measurements can be explained with the example of the propane tanks. The propane tanks are an interesting technical challenge, as the propane boils at normal room temperature. The optimum way of storing propane is in liquid form, and that propane is kept in a liquid state at room temperature, it must be kept under pressure. In order to avoid the explosion liquid tanks must not be filled beyond 80 % of full capacity (volume), as the incompressible liquid propane changes at the temperature change.

liquid storage tanks; measurement; maintenance; storage

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

5-1-5-11.

2012.

objavljeno

Podaci o matičnoj publikaciji

Proceedings PLIN2012

Raos, Pero

Slavonski Brod: Strojarski fakultet Sveučilišta u Slavonskom Brodu

978-953-6048-62-5

Podaci o skupu

10th Natural Gas, Heat and Water Conference/ 3rd International Natural Gas, Heat and Water Conference

predavanje

26.09.2012-28.09.2012

Osijek, Hrvatska

Povezanost rada