Iterative Procedure for Determination of Synchronous Generator Load Point Using Finite Element Method (CROSBI ID 593507)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Petrinić, Miroslav ; Car, Stjepan ; Elez, Ante
engleski
Iterative Procedure for Determination of Synchronous Generator Load Point Using Finite Element Method
Periodical changes in the magnetic field of a synchronous generator, and its mechanical or electrical unbalances, have effect on the armature voltage, current and electromagnetic forces. Determination of these values during the design stage of a machine gives insight in its possible operation problems, and enables their easier prevention. Quantities of interest can be determined by using the finite element method calculations. However, in order to obtain data that correspond to real working conditions of a machine, simulations of different operation points have to be done. The procedure described here provides algorithm for determination of synchronous generator load condition parameters. It relates to symmetrical 3-phase load, it is based on physically measurable values, and can be universally used on any synchronous generator with field winding. This method was applied on a 34 MVA generator and the obtained results show good agreement with the measured data.
detection algorithms; electric machines;
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
7 str-x.
2012.
objavljeno
Podaci o matičnoj publikaciji
XXth International Conference on Electrical Machines, ICEM 2012 : Proceedings, Marseille, France, September 2-5, 2012.
Nogueiras Meléndez, Andrés A.
Danver (MA): Institute of Electrical and Electronics Engineers (IEEE)
978-1-4673-0141-1
Podaci o skupu
XXth International Conference on Electrical Machines, ICEM 2012, Marseille, France, September 2-5, 2012.
predavanje
02.09.2012-05.09.2012
Marseille, Francuska