Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Prognostic performance of the Simplified Acute Physiology Score II in major Croatian hospitals: a prospective multicenter study (CROSBI ID 187618)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Deša, Kristian ; Perić, Mladen ; Husedžinović, Ino ; Šustić, Alan ; Korušić, Anđelko ; Karadža, Vjekoslav ; Matleković, Dražen ; Prstec-Veronek, Branka ; Žuvić- Butorac, Marta ; Sokolić, Jadranko et al. Prognostic performance of the Simplified Acute Physiology Score II in major Croatian hospitals: a prospective multicenter study // Croatian medical journal, 53 (2012), 5; 442-449. doi: 10.3325/cmj.2012.53.442

Podaci o odgovornosti

Deša, Kristian ; Perić, Mladen ; Husedžinović, Ino ; Šustić, Alan ; Korušić, Anđelko ; Karadža, Vjekoslav ; Matleković, Dražen ; Prstec-Veronek, Branka ; Žuvić- Butorac, Marta ; Sokolić, Jadranko ; Širanović, Mladen ; Bošnjak, Danica ; Špiček Macan, Jasna ; Guštin, Denis ; Ožeg-Jakopović, Draženka

engleski

Prognostic performance of the Simplified Acute Physiology Score II in major Croatian hospitals: a prospective multicenter study

Aim: To perform an external validation of the original Simplified Acute Physiology Score II (SAPS II) system and to assess its performance in a selected group of patients in major Croatian hospitals. Methods: A prospective, multicenter study was conducted in five university hospitals and one general hospital during a six-month period between November 1, 2007 and May 1, 2008. Standardized hospital mortality ratio (SMR) was calculated from the mean predicted mortality of all the 2756 patients and the actual mortality for the same group of patients. The validation of SAPS II was made using the area under receiver operating characteristic curve (AUC), 2 × 2 classification tables, and Hosmer-Lemeshow tests. Results The predicted mortality was as low as 14.6% due to a small proportion of medical patients and the SMR being 0.89 (95% confidence interval [CI], 0.78-0.98). The SAPS II system demonstrated a good discriminatory power as measured by the AUC (0.85 ; standard error [SE] = 0.012 ; 95% CI = 0.840-0.866 ; P < 0.001). This system significantly overestimated the actual mortality (Hosmer-Lemeshow goodness-of-fit H statistic: χ2 = 584.4 ; P < 0.001 and C statistics: χ2 8 = 313.0 ; P < 0.001) in the group of patients included in the study. Conclusion: The SAPS II had a good discrimination, but it significantly overestimated the observed mortality in comparison with the predicted mortality in this group of patients in Croatia. Therefore, caution is required when an evaluation is performed at the individual level.

SAPS II system; anaesthesia

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

53 (5)

2012.

442-449

objavljeno

0353-9504

10.3325/cmj.2012.53.442

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost