External quality assessmenr in clinical chemistry : review of the Croatian situation with particular reference to equipment (CROSBI ID 90809)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Juretić, Dubravka ; Čepelak, Ivana ; Flegar-Meštrić, Zlata External quality assessmenr in clinical chemistry : review of the Croatian situation with particular reference to equipment // Clinical chemistry and laboratory medicine, 37 (1999), 6; 667-673-x

Podaci o odgovornosti

Juretić, Dubravka ; Čepelak, Ivana ; Flegar-Meštrić, Zlata

engleski

External quality assessmenr in clinical chemistry : review of the Croatian situation with particular reference to equipment

The effect of the use of new flame photometers (Ciba Corning 480) and multichannel analyzers (BM Hitachi 904 or BM Hitachi 911) on the analytical quality was assessed in a number of medical biochemical laboratories (n=58) at health centers and general hospitals that provide primary health care services for the respective catchment areas. These laboratories were supplied during 1996 and 1997 with new equipment, as part of the First Croatian Health Project, Primary Health Care Subproject exercised by the Croatian Ministry of Health and Croatian Institute of Health Insurance. Therefore, we evaluated analytical performance of these laboratories for nineteen analytes, according to their results reported in the Croatian External Quality Assessment Program for medical biochemical laboratories, performed four times per year. Changes of percentages of particular methods used by the participating laboratories were observed for inorganic phosphate, total bilirubin, urea and creatinine. The changes were even more pronounced in the category of enzymes, where changes in the measurement procedure such as incubation temperature and buffers were observed in the methods used. Evaluation of method performance revealed that after the introduction of new equipment, more sensitive and more specific methods for determination of particular serum components had now been used, and interlaboratory variation reduced, so that an ever increasing proportion of medical biochemical laboratories included in the Project produced results within the target limits.