Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Comparison of the "Ssdwlab 5.0.9" and "Fetal Medicine Foundation" Down syndrom screening softwares (CROSBI ID 590965)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Radeljak, A ; Podobnik Brlečić, P ; Ožvald, I ; Gebauer Vuković, B ; Podobnik, M ; Stojanović, N. Comparison of the "Ssdwlab 5.0.9" and "Fetal Medicine Foundation" Down syndrom screening softwares // Biochemia medica / Šimundić, AM (ur.). 2012. str. A181-A182

Podaci o odgovornosti

Radeljak, A ; Podobnik Brlečić, P ; Ožvald, I ; Gebauer Vuković, B ; Podobnik, M ; Stojanović, N.

engleski

Comparison of the "Ssdwlab 5.0.9" and "Fetal Medicine Foundation" Down syndrom screening softwares

Background. First trimetser screening by a combination of maternal age, fetal nuchal translucency and maternal serum free-b-hCG and PAPP-A can identify about 85-90% of fetuses with trisomy 21 and other mayor aneuploidies. The aim of this study was to compare risk calculations performed using two different softwares. materials and methods. PAPP-A and free-b-hCG concentrations were measured by electrochemiluminescent immunoassay /ECL) on Roche Elecsys analyzer. The obtained results were within the target values of internal and external quality assurance programme (UKNEQAS scheme for First Trimester Downs Syndrome Screening). Nuchal translucency was measured by sonographers with FMF Certificate of Competence. Risk calculations were performed using "SsdwLab 5.0.9" (Roche, certified by FMF) and "Fetal Medicine Foundation" softwares. Results. Patients (N=247) were devided into high, intermediate and low risk groups. The obtained distributions per group were: high risk 18 (7, 29%), intermediate risk 36 (14, 57%) and low risk 193(78, 14%)patients using SsdwLab 5.0.9 software vs. high risk 12 (4, 86%), intermediate risk 26 (10, 53%) and low risk 209 (84, 61%) patients using FMF software. 18 patients were classified as high risk by SsdwLab 5.0.9 vs. 10 (55, 6%) as high risk and 8 (44, 4%)as intermediate risk using FMF software. Only one fetus from the high risk group (by both softwares) was trisomy 21 positive, which was confirmed by amniocentesis. Conclusions. Comparing risk calculations performed using "SsdwLab 5.0.9" and "Fetal Medicine Foundation" softwares, we concluded that SSdwLab 5.0.9 calculates higher risk for the same input parameters. Further research will be aimed at discovering the causes of observed differences.

Down syndrom ; screening softwares

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

A181-A182.

2012.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Biochemia medica

Šimundić, AM

Zagreb: Hrvatsko društvo za medicinsku biokemiju i laboratorijsku medicinu (HDMBLM)

1330-0962

Podaci o skupu

2nd European Joint Congress of European Federatioin of Clinical Chemistry and laboratory Medicine (EFCC) and European Union of Medical Specialists (UEMS)/ 7th Congrerss of Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM)

poster

10.10.2012-13.10.2012

Dubrovnik, Hrvatska

Povezanost rada

Kliničke medicinske znanosti

Indeksiranost