Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Verification of the Body Fluid Application on the Sysmex XE-5000 Hematology Analyzer (CROSBI ID 590949)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Šiftar, Zoran ; Kardum Paro, Mirjana Mariana ; Nazor, Aida ; Sokolić, Ivica ; Kardum Skelin, Ika ; Flegar- Meštrić, Zlata. Verification of the Body Fluid Application on the Sysmex XE-5000 Hematology Analyzer // Biochemia medica / Šimundić, AM (ur.). 2012. str. A118-A118

Podaci o odgovornosti

Šiftar, Zoran ; Kardum Paro, Mirjana Mariana ; Nazor, Aida ; Sokolić, Ivica ; Kardum Skelin, Ika ; Flegar- Meštrić, Zlata.

engleski

Verification of the Body Fluid Application on the Sysmex XE-5000 Hematology Analyzer

Background. Aim of this study is to investigate the performance of BF application on the Sysmex XE-5000 hematology analyzer in differential diagnosis of exudates and transudates. Materials and methods. The XE-5000 BF application provides white blood cell (BF-WBC) and total nucleated cell (BF-TC), as well as erythrocyte (BF-ERC) count. BF-WBC is further subcategorized in mononuclear and polymorphonuclear cells, BF-MN and BF-PMN. Performance of application was evaluated according to CLSI H56-A guidelines. Comparison to reference methods: microscopic cell counting in Neubauer chamber and differential on MGG stained smears after citospin preparation were done. Additionally, measurement of cells on XS2100 analyzer was included in comparative study. Automated cell counting was performed in Institute of Clinical Chemistry and Laboratory Medicine, whilst the microscopic in Institute of Clinical Cytology and Cytogenetics. It was done on various fluids (pleural effusion and ascites, dialysis fluid within peritoneal dialysis treatment) specimens. For correlation calculation Passing and Bablock regression analysis is used. Results. Repeatability of BF-WBC measurements was performed on 3 concentration levels. Coefficients of variation (CVs) were 21, 14 and 7.5, and met manufacturer specifications. BF-WBC linearity was proven for measurement range of 3 to 3420. Achieved coefficients of correlation with microscopic and measured counts on Sysmex XE 2100 for 35 specimens were 0.92 and 0.98, respectively. Obtained coefficient of 0.89 was found in comparison of automated and microscopic differential on 23 samples. Conclusions. Evaluation of BF application on Sysmex XE-5000 showed significant improvement in the ability of automated hematology analyzers regarding body fluid cell count analysis.

body fluid application; verification; hematology analyzer

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

A118-A118.

2012.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Biochemia medica

Šimundić, AM

Zagreb: Hrvatsko društvo za medicinsku biokemiju i laboratorijsku medicinu (HDMBLM)

1330-0962

Podaci o skupu

2nd European Joint Congress of European Federation of Clinical Chemistry and Laboratory Medicine (EFCC) and European Union of Medical Specialists (UEMS)/7th Congress of Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM)

poster

10.10.2012-13.10.2012

Dubrovnik, Hrvatska

Povezanost rada

Temeljne medicinske znanosti, Kliničke medicinske znanosti

Indeksiranost