Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

A method of preparing frersh blood samples for Croatian haematology external quality assessment (CROSBI ID 590946)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Nazor A ; Flegar-Meštrić, Z ; Hećimović, A ; Šiftar, Z ; Hundrić Hašpl, Ž. A method of preparing frersh blood samples for Croatian haematology external quality assessment // Biochemia medica / Šimundić, AM (ur.). 2012. str. A117-A117

Podaci o odgovornosti

Nazor A ; Flegar-Meštrić, Z ; Hećimović, A ; Šiftar, Z ; Hundrić Hašpl, Ž.

engleski

A method of preparing frersh blood samples for Croatian haematology external quality assessment

Background. Croatian EQA involves participation in the National External Quality Assurance Scheme organized under the auspices of the Croatian Society of Medical Biochemists by processing of unknown samples 3 times per annum. The suitability of home-made control material for complete blood count was evaluated. Materials and methods. The Croatian Institute for Transfusion Medicine prepared the homemade control material for complete blood count. A single portion of fresh blood is used given by voluntary donor having given consent to its intending use. A minor portion of the blood is tested for Hepatitis B and C as well as HIV and TP and was nonreactive for all these markers. After 30 minutes mixing in a way without making foam, 1, 5 ml K2EDTA molarity 1 mol/L is added and the mixing was continued next 2-5 minutes. The blood is distributed into suitable 7, 5 x 12 mm sterile tubes, capped and stored at +2 to +8 C. The samples were analyzed for homogeneity and stability accordiing to the ISO 13528 requirements. Results. The home made samples are delivered within 24 hours throughout Croatia in 200 medical biochemistry laboratories and are analyzed on 37 different types of analyzers from 11 different manufacturers. Assessment against consensus values and the percent allowed difference score is introduced for evaluation of obtained results. The high degree of inter-laboratory comparability is approved. Conclusion. The home made control material used in Croatian EQA scheme shows applicability to all haematological analyzers and provides a long term, retrospective assessment of laboratory performance and comparability of results on national level.

fresh blood samples; EQA

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

A117-A117.

2012.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Biochemia medica

Šimundić, AM

Zagreb: Hrvatsko društvo za medicinsku biokemiju i laboratorijsku medicinu (HDMBLM)

1330-0962

Podaci o skupu

2nd European Joint Congress of European Federation of Clinical Chemistry and Laboratory Medicine (EFCC) and European Union of Medical Specialists (UEMS)/7th Congress of Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM)

poster

10.10.2012-13.10.2012

Dubrovnik, Hrvatska

Povezanost rada

Temeljne medicinske znanosti

Indeksiranost