Laser Interferometry Measuring of Glass Ionomer Dimensional Changes


Prskalo, Katica; Spajić, Jelena; Šariri, Kristina; Demoli, Nazif; Janković, Bernard; Klarić, Eva; Tarle, Zrinka
Laser Interferometry Measuring of Glass Ionomer Dimensional Changes // Journal of Dental Research, Vol. 91, Special Issue C
Helsinki, Finska, 2012. (poster, međunarodna recenzija, sažetak, znanstveni)


Naslov
Laser Interferometry Measuring of Glass Ionomer Dimensional Changes

Autori
Prskalo, Katica ; Spajić, Jelena ; Šariri, Kristina ; Demoli, Nazif ; Janković, Bernard ; Klarić, Eva ; Tarle, Zrinka

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Journal of Dental Research, Vol. 91, Special Issue C / - , 2012

Skup
International Association for Dental Research Pan-European Region Meeting

Mjesto i datum
Helsinki, Finska, 12-15.09.2012

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Dimensional changes; Glass ionomers

Sažetak
Objectives: The aim of this study was to evaluate the linear dimensional changes of conventional glass ionomer cements during setting time period. Methods: Digital laser interferometry method was used to measure linear changes during setting of Ketac Molar Aplicap (KM) (Espe), Ketac Molar Quick Aplicap (KMQ) (Espe), Fuji IX Extra (FIXE) (GC) and Fuji IX Fast (FIXF) (GC). 10 discs specimens of 0.85mm thickness were prepared according to the manufacturer’s instructions for each tested material. The dimensional changes were recorded during setting time up to 7min. The results were analyzed by ANOVA and Tukey post hoc test (p<0.01). Results: All tested materials show initial setting expansion KM 0.28±0.13%, KMQ 2.41±1.09%, FIXE 0.03±0.03%, FIXF 0.26±0.21% and following setting shrinkage KM 0.47±0.13%, KMQ 0.62±0.33%, FIXE 1.22±0.38%, FIXF 1.32±0.57%. Ketac Molar Aplicap showed significantly lower shrinkage then Fuji IX Extra and Fuji IX Fast (p<0.01) and Ketac Molar Quick Aplicap showed significantly lower shrinkage then Fuji IX Fast (p<0.01). Conclusions: Unlike other methods, which are limited to finding information about the final dimensional changes, the laser interferometry method provides information in discrete increments of time during the desired period. In particular, Ketac Molar Quick Aplicap exhibited the highest expansion, while Ketac Molar Aplicap showed the lowest contraction. This study was supported by Ministry of Science , Education and Sports , Croatia (065-0352851-0410 and 035-0352851-2854)

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Dentalna medicina



POVEZANOST RADA


Projekt / tema
035-0352851-2854 - Razvoj digitalnih postupaka u holografiji i interferometriji (Nazif Demoli, )
065-0352851-0410 - Nanostruktura restaurativnih materijala i interakcije s tvrdim zubnim tkivima (Zrinka Tarle, )

Ustanove
Institut za fiziku, Zagreb,
Stomatološki fakultet, Zagreb