Impact of initial conditions on hysteretic behaviour of the boost converter (CROSBI ID 589357)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Pelin, Denis ; Ručević, Mia ; Vulin, Dragan
engleski
Impact of initial conditions on hysteretic behaviour of the boost converter
The different steady-state responses of a boost converter are observed during measurements carried out on the physical model of the chosen boost converter. It is shown that by varying the input voltage only, the boost converter exhibits hysteretic behavior. The various set of steady-state responses are recognized by increasing the dc input voltage regarding the set of steady state responses which are obtained by decreasing the dc input. Also, the steady-state responses of the boost converter are determined by means of computer simulation and presented in figure of bifurcation diagram. The results of computer simulation and results of experiment coincide very well for one trend of varying input voltage only. Therefore, impact of initial conditions of the state variables in the form of bifurcation diagram is studied
boost converter; steady-state responses; hysteretic behaviour; impact of initial condition
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
2012.
objavljeno
Podaci o matičnoj publikaciji
15th International Power Electronics and Motion Control Conference, EPE-PEMC 2012 ECCE Europe
Podaci o skupu
15th International Power Electronics and Motion Control Conference, EPE-PEMC 2012 ECCE Europe
poster
04.09.2012-06.09.2012
Novi Sad, Srbija