Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Application of alkaline solid residue of electric arc furnace dust for neutralization/purification of electroplating wastewaters (CROSBI ID 184668)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Elez, Loris ; Oreščanin, Višnja ; Sofilić, Tahir ; Mikulić, Nenad ; Ruk, Damir Application of alkaline solid residue of electric arc furnace dust for neutralization/purification of electroplating wastewaters // Journal of environmental science and health. Part A : Toxic/hazardous substances & environmental engineering, 43 (2008), 12; 1417-1423. doi: 10.1080/10934520802232121

Podaci o odgovornosti

Elez, Loris ; Oreščanin, Višnja ; Sofilić, Tahir ; Mikulić, Nenad ; Ruk, Damir

engleski

Application of alkaline solid residue of electric arc furnace dust for neutralization/purification of electroplating wastewaters

The purpose of thisworkwas development of an appropriate procedure for the neutralization/purification of electroplatingwastewater (EWW) with alkaline solid residue (ASR) by-product of the alkaline extraction of zinc and lead from electric arc furnace dust (EAFD). Removal efficiency of ASR at optimum purification conditions (pH 8 and mixing time ; 20 minutes) for the elements Pb, Cr (VI), Cr (III), Fe, Ni, Cu and Zn were 94.92%, 97.58%, 99.59%, 99.48%, 97.25% and 99.97%, respectively. The concentrations of all elements in the purified wastewater were significantly lower in relation to the upper permissible limit for wastewaters suitable for discharge into the environment. The remaining waste mud was regenerated in the strong alkaline medium and successfully applied once again for the neutralization/purification of EWW. Removal efficiencies of heavy metals accomplished with regenerated waste mud were comparable to these achieved by original ASR. Elemental concentrations in the leachates of the waste mud were in acordance with regulated values

electric arc furnace dust ; alkaline extraction ; alkaline solid residue ; electroplating wastewater treatment ; mud regeneration

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

43 (12)

2008.

1417-1423

objavljeno

1093-4529

10.1080/10934520802232121

Povezanost rada

Kemija

Poveznice
Indeksiranost