Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Influence of substituent type and position on photooxidation of phenolic compounds : response surface methodology approach (CROSBI ID 184150)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kušić, Hrvoje ; Koprivanac, Natalija ; Papić, Sanja ; Lončarić Božić, Ana Influence of substituent type and position on photooxidation of phenolic compounds : response surface methodology approach // Journal of photochemistry and photobiology. A, Chemistry, 242 (2012), 1-12. doi: 10.1016/j.jphotochem.2012.05.026

Podaci o odgovornosti

Kušić, Hrvoje ; Koprivanac, Natalija ; Papić, Sanja ; Lončarić Božić, Ana

engleski

Influence of substituent type and position on photooxidation of phenolic compounds : response surface methodology approach

The combined influence of process (pH and [H2O2]) and structural (substituent type and position) parameters influencing the degradation of phenolic pollutants in water by UV/H2O2 processes is studied using modified miscellaneous 34 full factorial design and response surface methodology (RSM). The model wastewaters consisted of eight phenolic pollutants containing hydroxyl (-OH), chloro (-Cl), nitro (-NO2), and methyl (-CH3) substituents in ortho and para position. It was determined that all studied phenols obey first-order degradation kinetic, which is influenced significantly by all studied process and structural parameters. The quadratic polynomial model is used to describe these effects. Different optimal operating conditions and values of observed first-order degradation rate constants (kobs) were determined for each of the phenolic pollutants indicating the significant influence of type and position of substituent to parent pollutant degradation and structurally determined degradation pathway. kobs were correlated with the second-order degradation rates with hydroxyl radicals (kHO•) as well as with several physical and structure related properties of studied phenolics using Spearman rank coefficient.

wastewater; phenols; photooxidation; response surface modeling; structural-relationship

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

242

2012.

1-12

objavljeno

1010-6030

10.1016/j.jphotochem.2012.05.026

Povezanost rada

Kemijsko inženjerstvo

Poveznice
Indeksiranost