Modified GPC Controller for Control of Processes with Long Dead-Time and Integral Action (CROSBI ID 183342)

Prilog u časopisu | izvorni znanstveni rad

Jolevski, Danijel ; Bego, Ozren ; Goić, Ranko Modified GPC Controller for Control of Processes with Long Dead-Time and Integral Action // International review of automatic control, 4 (2011), 2; 162-169

Podaci o odgovornosti

Jolevski, Danijel ; Bego, Ozren ; Goić, Ranko

engleski

Modified GPC Controller for Control of Processes with Long Dead-Time and Integral Action

Processes with dead time are the processes with time lags between output and input. Time lags aggravate control by reducing the phase margin of the closed-loop control. At dead time, integral action causes an additional problem with the control of such a process. This paper presents a modified GPC controller, and compares the modified GPC controller with the controllers mainly used today for such a process type. Modified GPC controller contains a part that takes into account the disturbance dynamics in the past and future. The use of the modified GPC controller can completely eliminate the impact of disturbance on the controlled value, if the change of disturbance is known in the future in the quantity of dead time. However, if the value of disturbance is not known in the future, the improvement is still reached, because this part takes into account the disturbance dynamics in the past. Simulated results were obtained for the process of water level control in Lipa compensation basin, and the conclusions on the quality of individual controllers in the time domain were made.

Modified GPC Controller; Long Dead-Time; Integral Action; Smith Controller; Modified Smith Controller; Water Level Control

Rad spada u kategoriju B jer je objavljen u časopisu koji je zastupljen u Cambridge Scientific Abstracts bazi (NN 84/05.)

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

4 (2)

2011.

162-169

objavljeno

1974-6059

Povezanost rada

Elektrotehnika