Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Use of precise digital voltmeters for phase measurements (CROSBI ID 90194)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Ilić, Damir ; Butorac, Josip Use of precise digital voltmeters for phase measurements // IEEE transactions on instrumentation and measurement, 50 (2001), 2; 449-452-x

Podaci o odgovornosti

Ilić, Damir ; Butorac, Josip

engleski

Use of precise digital voltmeters for phase measurements

The possibility of using high-resolution digital voltmeters for ac voltage measurements at a frequency of about 16 Hz is presented. The method of approximate synchronous sampling is used where each sample is measured as the mean value of the one-third cycle of a period. From the samples, the rms value of the "derived" sine is determined using subsequent numeric synchronization, while the phase angle of the first sample is calculated as regression line coefficient. Corrections of phase differences between two voltmeters were determined using only one source in cascade measurements.

phase difference measurement; digital voltmeters; ac voltage; complex voltage ratio measurement

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

50 (2)

2001.

449-452-x

objavljeno

0018-9456

Povezanost rada

Elektrotehnika

Indeksiranost