Dokazivanje Au3+, V5+, Ti+, TI3+, Ce4+, Th4+, UO22+, Pt4+, Se(IV) i Te(IV)u smjesi tankoslojnom kromatografijom
The possibility of identifying of Au3+, V5+, Ti+, TI3+, Ce4+, Th4+, UO22+, Pt4+, Se(IV) and Te(IV) in the sample solution by thin layer chromatography (TLC) was investigated. Microcrystalline cellulose for TLC from E. Merck was used as a thin layer. A mixture of ion solutions was applied on three spots and the development was carried out by ascending technique. After development, the plate was divided into three areas, and each surface was sprayed with one detection agent. Numerous solvent systems for developing were also investigated.
*
nije evidentirano
engleski
Identification of Au3+, V5+, Ti+, TI3+, Ce4+, Th4+, UO22+, Pt4+, Se(IV) and Te(IV) in a mixture by thin layer chromatography
nije evidentirano
Thin layer chromatography; Cellulose; Cerium; Gold; Ions; Platinum; Selenium; Solvents; Tellurium; Thallium; Thorium; Titanium; Vanadium