Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Problems Related to Excitation Winding Surface Temperature Measurement of a Salient Pole Synchronous Generator in Rotation (CROSBI ID 181350)

Prilog u časopisu | izvorni znanstveni rad

Hanić, Zlatko ; Vražić, Mario ; Stipetić, Stjepan Problems Related to Excitation Winding Surface Temperature Measurement of a Salient Pole Synchronous Generator in Rotation // Journal of energy and power engineering, 6 (2012), 5; 826-832

Podaci o odgovornosti

Hanić, Zlatko ; Vražić, Mario ; Stipetić, Stjepan

engleski

Problems Related to Excitation Winding Surface Temperature Measurement of a Salient Pole Synchronous Generator in Rotation

Paper addresses some of the problems related to direct surface temperature measurement of a salient pole synchronous generator excitation winding in rotation. Excitation winding temperature is used for determining the dynamic limit in a PQ diagram. The paper also addresses procedures of improving the accuracy of surface temperature measurement using the contact DS18B20 digital temperature probes. The paper also provides experimental results of direct temperature measurement of the excitation winding surface conducted in the salient pole synchronous generator in the rotation.

temperature measurement; AC machines; synchronous generators; excitation winding; wireless sensing; digital temperature sensors

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

6 (5)

2012.

826-832

objavljeno

1934-8975

1934-8983

Povezanost rada

Elektrotehnika