Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

A one-step real-time multiplex PCR for screening Y-chromosomal microdeletions without downstream amplicon size analysis (CROSBI ID 178706)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kozina , Viviana ; Cappallo - Obermann , Heike ; Gromoll Jorg ; Spiess , Andrej - Nikolai A one-step real-time multiplex PCR for screening Y-chromosomal microdeletions without downstream amplicon size analysis // PLoS One, 6 (2011), 8; doi: 10.1371/journal.pone.0023174

Podaci o odgovornosti

Kozina , Viviana ; Cappallo - Obermann , Heike ; Gromoll Jorg ; Spiess , Andrej - Nikolai

engleski

A one-step real-time multiplex PCR for screening Y-chromosomal microdeletions without downstream amplicon size analysis

BACKGOUND: Y-chromosomal microdeletions (YCMD) are one of the major genetic causes for non-obstructive azoospermia. Genetic testing for YCMD by multiplex polymerase chain reaction (PCR) is an established method for quick and robust screening of deletions in the AZF regions of the Y-chromosome. Multiplex PCRs have the advantage of including a control gene in every reaction and significantly reducing the number of reactions needed to screen the relevant genomic markers. PRINCIPAL FINDINGS: The widely established "EAA/EMQN best practice guidelines for molecular diagnosis of Y-chromosomal microdeletions (2004)" were used as a basis for designing a real-time multiplex PCR system, in which the YCMD can simply be identified by their melting points. For this reason, some AZF primers were substituted by primers for regions in their genomic proximity, and the ZFX/ZFY control primer was exchanged by the AMELX/AMELY control primer. Furthermore, we substituted the classical SybrGreen I dye by the novel and high-performing DNA-binding dye EvaGreen™ and put substantial effort in titrating the primer combinations in respect to optimal melting peak separation and peak size. SIGNIFICANCE: With these changes, we were able to develop a platform-independent and robust real-time based multiplex PCR, which makes the need for amplicon identification by electrophoretic sizing expendable. By using an open-source system for real-time PCR analysis, we further demonstrate the applicability of automated melting point and YCMD detection.

Y-chromosomal microdeletions; real-time PCR; multiplex PCR; EvaGreen; melting curve analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

6 (8)

2011.

objavljeno

1932-6203

10.1371/journal.pone.0023174

Povezanost rada

nije evidentirano

Poveznice
Indeksiranost