Echocardiography in detecting implantable cardioverter defibrillator lead endocarditis: case report (CROSBI ID 175676)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Vincelj J, Baršić B, Rudež I, Unić D, Udovičić M. Echocardiography in detecting implantable cardioverter defibrillator lead endocarditis: case report // Acta clinica Croatica, 50 (2011), 1; 121-124

Podaci o odgovornosti

Vincelj J, Baršić B, Rudež I, Unić D, Udovičić M.

engleski

Echocardiography in detecting implantable cardioverter defibrillator lead endocarditis: case report

Lead endocarditis is an infrequent but potentially lethal complication of implantable cardioverter defibrillator (ICD) implantation. We report a case of a 53-year-old man with ICD who was admitted to our hospital because of fever, chills, shivering, headache and malaise. Transthoracic echocardiography detected a structure highly suspect of vegetation located on the ICD lead. Transesophageal echocardiography showed a 20x12 mm mobile vegetation attached to the ICD lead in the right atrium. The infection was caused by methicillin-resistant Staphylococcus epidermidis (MRSE), which was isolated from blood cultures. Treatment consisted of surgical removal of the ICD lead and placement of new epicardial ICD leads. Three years afterwards, the patient remained asymptomatic. To our knowledge, this is the first such case reported from Croatia.

endocarditis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

50 (1)

2011.

121-124

objavljeno

0353-9466

Povezanost rada

nije evidentirano

Indeksiranost