The Effects of Asymetric Flows in the Coriolis Mass Flowmeter with the Straight Parallel Tubes: Numerical Simulation (CROSBI ID 476630)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Kesić, Petar ; Damić, Vjekoslav The Effects of Asymetric Flows in the Coriolis Mass Flowmeter with the Straight Parallel Tubes: Numerical Simulation // FLOMEKO 2000. Salvador: IPM, 2000. str. CD ROM-x

Podaci o odgovornosti

Kesić, Petar ; Damić, Vjekoslav

engleski

The Effects of Asymetric Flows in the Coriolis Mass Flowmeter with the Straight Parallel Tubes: Numerical Simulation

The effects of flow disturbances on the performance of the Coriolis mass flowmeter(CMF) with two straight parallel tubes were invetigated numerically. Two types of flow disturbances were studied numerically using the bond-graph presentation. The first one represents a local restriction in one of the pipes that causes asymmeric flow in pipes. In the second case of operating conditions, uniformly obliterated tubes were considered. The effect of the obliterated layer thickness with different densities was analysed. It was found that the local restriction at the tube entrance does not effect the sensitivity coefficient, while the flowrate in the tube changes from zero to a rate equal to that in the parallel tube. The obliteration does not effect the sensitivity coefficient either, but changes the first natural mode of tube vibration. If the CMF is used for density measurement, the obliteration may cause significant error.

Coriolis mass flowmeter; mass flowmeter; fluid flowrate; bond

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

CD ROM-x.

2000.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

FLOMEKO 2000

Salvador: IPM

Podaci o skupu

FLOMEKO 2000, The 10-th International Conference on Flow Measurement, IMEKO

predavanje

04.06.2000-08.06.2000

Brazil; Salvador

Povezanost rada

Brodogradnja, Zrakoplovstvo, raketna i svemirska tehnika