Pregled bibliografske jedinice broj: 523196
Comparison of Ventilation Threshold And Heart Rate Deflection Point In Fast And Standard Treadmill Test Protocol
Comparison of Ventilation Threshold And Heart Rate Deflection Point In Fast And Standard Treadmill Test Protocol // Proceedings Book of 6th International Scientific Conference on Kinesiology, Integrative Power Of Kinesiology / Milanović, D ; Sporiš, G ; (ur.).
Opatija: Faculty of Kinesiology, University of Zagreb, Croatia, 2011. str. 667-671 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 523196 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of Ventilation Threshold And Heart Rate Deflection Point In Fast And Standard Treadmill Test Protocol
(Comparison Ventilation Threshold And Heart Rate Deflection Point In Fast And Standard Treadmill Test Protocol)
Autori
Sporiš, Goran ; Vučetić, Vlatko ; Šentija, Davor ;
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings Book of 6th International Scientific Conference on Kinesiology, Integrative Power Of Kinesiology
/ Milanović, D ; Sporiš, G ; - Opatija : Faculty of Kinesiology, University of Zagreb, Croatia, 2011, 667-671
ISBN
978-953-317-013-8
Skup
Proceedings Book of 6th International Scientific Conference on Kinesiology, Integrative Power Of Kinesiology
Mjesto i datum
Opatija, Hrvatska, 08.09.2011. - 11.09.2011
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
ventilation anaerobic threshold; heart rate deflection point; treadmill test; ramp exercise protocol; exercise
Sažetak
The purpose of the study was to compare two methods for determination anaerobic threshold from two different treadmill protocols. Forty-eight Croatian runners of national rank participated in the study (10 sprinters, 15 400m runners, 10 middle distance runners and 13 long distance runners) with a mean age of 21.7 ± 5.1 years performed two graded maximal exercise test on a treadmill, Standard ramp treadmill test protocol (TSR - speed increments of 1 km/h every 30 seconds) and Fast ramp treadmill test protocol (TFR - speed increments of 1 km/h every 60 seconds) to determine and compare parameters at peak values and at HRDP and VT. There were no significant differences between peak values at mean VO2 (4.48 vs 4.44 L/min), weight related VO2 (RVO2 - 62.52 vs 62.04 mL/kg/min), pulmonary ventilation (VE – 163.09 vs 161.29 L/min) and heart rate (192.35 vs 194.44 beats/min), that were measured in both protocol (TFR and TSR). Significant differences were found between running speed at anaerobic thresholds (vAnT) achieved in two different protocols, independent which methods for determination AnT were used (vAnT - 16.01 vs 14.94 km/h in VT methods and vAnT -16.46 vs 14.95 km/h in HRDP methods, respectively). Linear regression analysis revealed a correlation of 0.86 (p < 0.01) in TFR and 0.77 in TSR (p < 0.01) protocols between RVO2 measured at VT and RVO2 measured at HRDP, so the present study indicates that the point of deflection from linearity of heart rate (HRDP) may be an accurate predictor of VT for VO2 and HR in runners with predominantly aerobic or anaerobic energy contribution independently of used protocol. In the same time, we conclude that RQmax, achieved running speed and running speed at anaerobic thresholds are protocol dependent values
Izvorni jezik
Engleski
Znanstvena područja
Računarstvo
POVEZANOST RADA
Projekti:
034-0342618-2222 - Razvoj algoritama za testiranje multivarijatnih strukturalnih hipoteza
Ustanove:
Kineziološki fakultet, Zagreb