Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

As(V) removal from drinking water by coagulation and filtration through immersed membrane (CROSBI ID 173119)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Ćurko, Josip ; Mijatović, Ivan ; Matošić, Marin ; Korajlija Jakopović, Helena ; Ujević Bošnjak, Magdalena As(V) removal from drinking water by coagulation and filtration through immersed membrane // Desalination, 279 (2011), 1/3; 404-408. doi: 10.1016/j.desal.2011.06.043

Podaci o odgovornosti

Ćurko, Josip ; Mijatović, Ivan ; Matošić, Marin ; Korajlija Jakopović, Helena ; Ujević Bošnjak, Magdalena

engleski

As(V) removal from drinking water by coagulation and filtration through immersed membrane

In this work we investigated As(V)removal by coagulation with FeCl3 as coagulant combined with microfiltration through immersed membrane. The adsorption capacity of the coagulant was determined and the continuous removal of arsenic was performed with special emphasis on the membrane fouling rate. During a continuous experiment in a reactor with an immersed membrane, tap water was spiked with 100 µg/L of As(V) and treated with 5.16 mg Fe(III)/L. During the experiment, the concentration of As(V) in treated water was always under 10 µg/L. The configuration of the membrane allowed the maintaining of a high permeate flow rate at 60 L/m2 h. Membrane fouling was mostly caused by the precipitation of scale on the membrane surface and into the membrane pores which contributed 50% to the total resistance while the cake resistance contribution to total resistance was low and reached 15% at the end of the experiment when suspended matter in the reactor reached 8.85 g/L. The initial permeability of the membrane could be restored by chemical cleaning with oxalic acid. The investigated process showed good efficiency and stability in removing As(V) from drinking water.

arsenic; coagulation; immersed membrane; membrane fouling

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

279 (1/3)

2011.

404-408

objavljeno

0011-9164

10.1016/j.desal.2011.06.043

Povezanost rada

Biotehnologija

Poveznice
Indeksiranost