Numerical and experimental strength analysis of fire-tube boiler construction (CROSBI ID 172679)
Prilog u časopisu | prethodno priopćenje
Podaci o odgovornosti
Gaćeša, Branka ; Vesna, Milošević-Mitić ; Maneski, Taško ; Kozak, Dražan ; Sertić, Josip
engleski
Numerical and experimental strength analysis of fire-tube boiler construction
Norms, such as EN 12952-3 and EN 12953-3 handle the issues concerned with calculation of the pressurized boiler components, not however considering the influences of thermal strains that are often of vital importance for the integrity of boiler's construction.Application ofFEMin boiler design inENis suggested in calculating all components that are not covered by the norm. In this way, the calculation of thermal stress is left to the free will of designer and technical inspectorate which supervises and approves placement of a boiler into operation. This paper demonstrates that the influence of thermal stresses is great and that it must be taken into consideration when the boiler's construction is designed and its working life evaluated. It is shown that for every construction a numericalexperimental behaviour diagnostics should be conducted prior to putting it into operation. First, a numerical model must be experimentally verified and then it can be used in considering different parameters of strength diagnostics, such as distribution of membrane and bending stresses for substructures, and distribution of deformation energy. They indicate, in an optimal way, root causes of insufficiently good behaviour of the construction. Also, a dynamical calculation of natural oscillations should always be suggested.
deformation energy; experiment; finite element analysis; steam-boiler; stress; temperature
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
18 (2)
2011.
237-242
objavljeno
1330-3651