Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Comparison between non-linear dynamic and static seismic analysis of structures according to European and US provisions (CROSBI ID 170402)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Čaušević, Mehmed ; Mitrović, Saša Comparison between non-linear dynamic and static seismic analysis of structures according to European and US provisions // Bulletin of earthquake engineering, 9 (2011), 2; 467-489. doi: 10.1007/s10518-010-9199-1

Podaci o odgovornosti

Čaušević, Mehmed ; Mitrović, Saša

engleski

Comparison between non-linear dynamic and static seismic analysis of structures according to European and US provisions

Several procedures for non-linear static and dynamic analysis of structures have been developed in recent years. This paper discusses those procedures that have been implemented into the latest European and US seismic provisions: non-linear dynamic time-history analysis ; N2 non-linear static method (Eurocode 8) ; non-linear static procedure NSP (FEMA 356) and improved capacity spectrum method CSM (FEMA 440). The presented methods differ in respect to accuracy, simplicity, transparency and clarity of theoretical background. Non-linear static procedures were developed with the aim of overcoming the insufficiency and limitations of linear methods, whilst at the same time maintaining a relatively simple application. All procedures incorporate performance-based concepts paying more attention to damage control. Application of the presented procedures is illustrated by means of an example of an eight-storey reinforced concrete frame building. The results obtained by non-linear dynamic time-history analysis and non-linear static procedures are compared. It is concluded that these non-linear static procedures are sustainable for application. Additionally, this paper discusses a recommendation in the Eurocode 8/1 that the capacity curve should be determined by pushover analysis for values of the control displacement ranging between zero and 150% of the target displacement. Maximum top displacement of the analyzed structure obtained by using dynamic method with real time-history records corresponds to 145% of the target displacement obtained using the non-linear static N2 procedure.

non-linear dynamic analysis; non-linear static methods; pushover analysis; N2; NSP and CSM methods

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

9 (2)

2011.

467-489

objavljeno

1570-761X

10.1007/s10518-010-9199-1

Povezanost rada

Geologija, Arhitektura i urbanizam, Građevinarstvo

Poveznice
Indeksiranost