Napredna pretraga

Pregled bibliografske jedinice broj: 504572

Simultaneous potentiometric determination of cationic and ethoxylated nonionic surfactants by use of a surfactant sensor


Samardžić, Mirela; Sak-Bosnar, Milan; Madunić-Čačić, Dubravka
Simultaneous potentiometric determination of cationic and ethoxylated nonionic surfactants by use of a surfactant sensor // Second Regional Symposium on Electrochemistry South-East Europe, Program & Book of Abstracts / Nikolić, Branislav ; Mišković-Stanković, Vesna ; Dekanski, Aleksandar (ur.).
Beograd: Serbian Chemical Society, 2010. str. 74-74 (poster, međunarodna recenzija, znanstveni)


Naslov
Simultaneous potentiometric determination of cationic and ethoxylated nonionic surfactants by use of a surfactant sensor

Autori
Samardžić, Mirela ; Sak-Bosnar, Milan ; Madunić-Čačić, Dubravka

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Second Regional Symposium on Electrochemistry South-East Europe, Program & Book of Abstracts / Nikolić, Branislav ; Mišković-Stanković, Vesna ; Dekanski, Aleksandar - Beograd : Serbian Chemical Society, 2010, 74-74

ISBN
978-86-7132-043-6

Skup
Second Regional Symposium on Electrochemistry South-East Europe

Mjesto i datum
Beograd, Srbija, 06-10.06.2010.

Ključne riječi
Surfactant sensor; cationic surfactant; ethoxylated nonionic surfactant; potentiometric titration

Sažetak
A sensitive potentiometric surfactant sensor based on 1, 3-didecyl-2-methylimidazolium-tetraphenylborate as a sensing ion-pair element served as an end-point detector in ion-pair surfactant potentiometric titrations using sodium tetraphenylborate as titrant. A few mixtures containing a cationic and ethoxylated nonionic surfactant were titrated potentiometrically. Barium ions forms pseudocationic complex with ethoxylated nonionic surfactant that can be titrated simultaneously with cationic surfactant using the same anionic titrant. Due to differences in hydrophobicity of both, nonionic and cationic surfactant investigated, ion associates formed during the titration revealed different stability constants resulting in two, more or less pronounced, analytically usable inflexions in the titration curve. The sensor showed satisfactory analytical performances within a pH range of two through eleven and was tested on several formulated powdered and liquid detergent products of various composition complexity too.

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Projekt / tema
291-0580000-0169 - Kemijski senzori za primjenu u biomedicini, hrani i zaštiti okoliša (Milan Sak-Bosnar)

Izvorni jezik
Engleski

Znanstvena područja
Kemija