Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The influence of ethoxylated nonionic surfactants on the potentiometric determination of anionic surfactants (CROSBI ID 169958)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Sak-Bosnar, Milan ; Samardžić, Mirela ; Galović, Olivera The influence of ethoxylated nonionic surfactants on the potentiometric determination of anionic surfactants // International journal of electrochemical science, 6 (2011), 3; 561-572

Podaci o odgovornosti

Sak-Bosnar, Milan ; Samardžić, Mirela ; Galović, Olivera

engleski

The influence of ethoxylated nonionic surfactants on the potentiometric determination of anionic surfactants

A PVC-plasticized liquid-type anionic surfactant (AS)-responsive sensor, using 1, 3-didecyl-2- methylimidazolium-tetraphenylborate (DMI-TPB) as the sensing element, has been utilized for the investigation of the influence of three ethoxylated nonionic surfactants (EONS), containing 8, 11 and 15 ethoxy (EO) groups, on the potentiometric determination of dodecyl sulfate (DS). The results demonstrate that the sensor slope (S) slowly decreased with increasing concentrations of EONS. The changes in the slope for the corresponding concentration change (DS:EONS ratios varied from 1:1 to 1:4) were 1.62, 5.11 and 6.28 mV for EONS containing 8, 11 and 15 EO groups, respectively. The constant potential term changes for the same EONS concentration change were 18.8, 22.3 and 39.5 mV, respectively. The linear response range became more narrow as the concentration of EONS increased, and increasing numbers of EO groups were found within the EONS molecule. There was a strong correlation between E and log DS a for all of the DS:EONS ratios in the linear region of the sensor response. The EONS molecules significantly influenced the potentiometric titration of DS. The titration curves were seriously disturbed for EONS:DS molar ratios greater than 5 for EONS containing 8 EO groups, for ratios greater than 3 for EONS containing 11 EO groups and for ratios greater than 2 for EONS containing 15 EO groups.

ion sensitive sensor; anionic surfactant; ethoxylated nonionic surfactant; potentiometric titration

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

6 (3)

2011.

561-572

objavljeno

1452-3981

Povezanost rada

Kemija

Indeksiranost