Napredna pretraga

Pregled bibliografske jedinice broj: 502854

The potential of 4D sonography in the assessment of fetal behavior in high risk pregnancies


Talić, Amira; Kurjak, Asim; Ahmed, Badreldeen; Stanojević, Milan; Predojević, Maja; Salihagić Kadić, Aida; Di Renzo; Gian Carlo
The potential of 4D sonography in the assessment of fetal behavior in high risk pregnancies // Journal of maternal-fetal & neonatal medicine, 24 (2011), 7; 948-954 doi:10.3109/14767058.2010.534830 (međunarodna recenzija, članak, znanstveni)


Naslov
The potential of 4D sonography in the assessment of fetal behavior in high risk pregnancies

Autori
Talić, Amira ; Kurjak, Asim ; Ahmed, Badreldeen ; Stanojević, Milan ; Predojević, Maja ; Salihagić Kadić, Aida ; Di Renzo ; Gian Carlo

Izvornik
Journal of maternal-fetal & neonatal medicine (1476-7058) 24 (2011), 7; 948-954

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Four dimensional ultrasound; fetus; behavior assessment; high risk pregnancy; neurologic deficit

Sažetak
Objective was to assess differences of fetal behavior in normal and high risk pregnancies. In the one year period (Jan 1, 2007-Dec 31, 2007), four dimensional ultrasound (4D US) has been used to assess Kurjak antenatal neurodevelopmental test (KANET) in low and high risk pregnancies after randomization in prospective longitudinal cohort study. Based on the KANET scores the fetuses were considered as normal (≥14 points), borderline (6- 13) or abnormal (0-5). Comparison of KANET scores in low and high risk pregnancies were expectedly statistically significant. The largest incidence of fetuses with abnormal KANET was in the group of fetuses who had siblings with cerebral palsy (CP). The largest incidence of the borderline KANET has been found in the group of fetuses whose mothers had fever during pregnancy. The following parameters of KANET test significantly differed between the fetuses from low and high risk pregnancies: overlapping cranial sutures, head circumference, isolated eye blinking, facial expressions, mouth movements, isolated hand movements, isolated leg movements, hand to face movement, finger movements and general movements (GM). KANET test has the potential to detect and discriminate normal from borderline and abnormal fetal behavior in normal and in high risk pregnancies.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti, Kliničke medicinske znanosti



POVEZANOST RADA


Projekt / tema
108-1081870-1940 - C/U omjer i motorički parametri u prevenciji perinatalnog oštećenja mozga (Aida Salihagić-Kadić, )

Ustanove
Medicinski fakultet, Zagreb,
Klinička bolnica "Sveti Duh"

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka:


  • MEDLINE


Citati