Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Spent radium sources conditioning operation in Croatia (CROSBI ID 475992)

Prilog sa skupa u zborniku | stručni rad

Vekić, Branko ; Kokot, Ljerka ; Trputec, Veljko ; Bokulić, Tomislav Spent radium sources conditioning operation in Croatia // Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe / Deme, Sandor (ur.). Budimpešta: Roland Eotvos Physical Society, 1999

Podaci o odgovornosti

Vekić, Branko ; Kokot, Ljerka ; Trputec, Veljko ; Bokulić, Tomislav

engleski

Spent radium sources conditioning operation in Croatia

Radium sources were used in Croatia for various applications in medicine and industry for many years. Due to their undesirable characteristics, almost all of these sources have been replaced by more modern sources. Storage of these unused sources, especially in developing countries, is often inadequate. Conditioning of radium sources for proper storage is one of major objective of the Waste Technology Section of IAEA. The conditioning of the spent radium sources in Croatia was performed by a specially trained team from the Austrial Research Center Seibersdorf, under contract to the IAEA, using an IAEA developed and approved procedure. The source conditioning took place in a waste storage and treatment facility at the Ruđer Bošković Institute, Zagreb, Croatia. The conditioning of the national radium stock in Croatia was performed within the period from 13-17 October 1997. The total inventory was 1316 mg (298 sources, 49 GBq). The sources were mainly needles and tubes. All spent radium sources were conditioned in 25 small capsules and one large capsule. The capsules were put into three shilding devices and two packages (drums) were produced. The total activity/shield is still under the transportation regulation limit. Experimental procedure was described and discussed. No complications in this operation were experienced. The operation caused no contamination and hence no decontamination was required.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1999.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe

Deme, Sandor

Budimpešta: Roland Eotvos Physical Society

Podaci o skupu

IRPA Regional Congress on Radiation Protection in Central Europe

poster

23.08.1999-27.08.1999

Budimpešta, Mađarska

Povezanost rada

Kemija