Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

3-D image analysis of abdominal aortic aneurysm (CROSBI ID 475942)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Subašić, Marko ; Lončarić, Sven ; Sorantin, Erich 3-D image analysis of abdominal aortic aneurysm // Medical Infobahn for Europe / / Hasman, A. ; Blobel, B. ; Dudeck, J. et al. (ur.). IOS Press, 2000. str. 1195-1200-x

Podaci o odgovornosti

Subašić, Marko ; Lončarić, Sven ; Sorantin, Erich

engleski

3-D image analysis of abdominal aortic aneurysm

In this paper we propose a technique for 3-D segmentation of abdominal aortic aneurysm (AAA) from computed tomography (CT) angiography images. Output data form the proposed method can be used for measurement of aortic shape and dimensions. Knowledge of aortic shape and size is very important for selection of appropriate stent graft device for treatment of AAA. The technique is based on a 3-D deformable model and utilizes the level-set algorithm for implementation of the method. The method performs 3?D segmentation of CT images and extracts a 3-D model of aortic wall. Once the 3-D model of aortic wall is available it is easy to perform all required measurements for appropriate stent graft selection. The method proposed in this paper uses the level-set algorithm instead of the classical active contour algorithm developed by Kass et al. The main advantage of the level set algorithm is that it enables easy segmentation surpassing most of the drawbacks of the classical approach. In the level-set approach for shape modeling, a 3-D surface is represented by a real 3-D function or equivalent 4-D surface. The 4-D surface is then evolved through an iterative process of solving the differential equation of surface motion. Surface motion is defined by velocity at each point. The velocity is a sum of constant velocity and curvature-dependent velocity. The stopping criterion is calculated based on image gradient. The algorithm has been implemented in MATLAB and C languages. Experiments have been performed using real patient CT angiography images and have shown good results.

3-D image analysis; deformable models; level set; image segmentation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1195-1200-x.

2000.

objavljeno

Podaci o matičnoj publikaciji

Medical Infobahn for Europe

/ Hasman, A. ; Blobel, B. ; Dudeck, J. ; Engelbrecht, R. ; Gell, G.

IOS Press

Podaci o skupu

MIE2000 and GMDS2000

predavanje

27.08.2000-01.09.2000

Hannover, Njemačka

Povezanost rada

Elektrotehnika