Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Gamma-ray signatures improvement of the EURITRACK tagged neutron inspection system database (CROSBI ID 167078)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

El Kanawati, W., Carasco, C., Perot, B., Mariani, A., Raoux, A.-C., Valković, Vladivoj ; Sudac, Davorin ; Obhođaš, Jasmina ; Baričević, Martina. Gamma-ray signatures improvement of the EURITRACK tagged neutron inspection system database // IEEE transactions on nuclear science, 57 (2010), 5; 2879-2885. doi: 0.1109/TNS.2010.2058864

Podaci o odgovornosti

El Kanawati, W., Carasco, C., Perot, B., Mariani, A., Raoux, A.-C., Valković, Vladivoj ; Sudac, Davorin ; Obhođaš, Jasmina ; Baričević, Martina.

engleski

Gamma-ray signatures improvement of the EURITRACK tagged neutron inspection system database

The EURopean Illicit TRAfficking Countermeasures Kit (EURITRACK) inspection system uses 14 MeV neutrons produced by the D(T, n α) reaction to detect explosives in cargo containers. Reactions induced by fast neutrons inside the container produce gamma rays, which are detected in coincidence with the associated alpha particle, the detection of which allows the neutron direction to be determined. The neutron path length is obtained from a neutron time-of-flight measurement, thus allowing the origin of the gamma rays inside the container to be determined, while the chemical composition of the target material is correlated with their energy spectrum. Gamma-ray spectra have been collected with the inspection portal equipped with large volume NaI (Tl) detectors, in order to build a database of signatures for various elements (C, O, N, Fe, Pb, Al, Na, Si, Cl, Cu, Zn) with a low energy threshold of 0.6 MeV. The spectra are compared with previous ones, which were acquired with a 1.35 MeV threshold. The new library is currently being tested to unfold the energy spectra of transported goods into elemental contributions. Results are compared with data processed with the old 1.35 MeV threshold database, thus illustrating the improvement for material identification.

gamma-ray signatures

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

57 (5)

2010.

2879-2885

objavljeno

0018-9499

0.1109/TNS.2010.2058864

Povezanost rada

Fizika

Poveznice
Indeksiranost