External Magnetic Field Density of Main Traction Transformer for EMU (CROSBI ID 567135)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Sitar, Ivan ; Janić, Žarko ; Ćućić, Branimir External Magnetic Field Density of Main Traction Transformer for EMU // Advanced Research Workshop on transformers ARWtr 2010 / Lopez-Fernandez, Xose M. (ur.). Vigo: University of Vigo, 2010. str. 348-353

Podaci o odgovornosti

Sitar, Ivan ; Janić, Žarko ; Ćućić, Branimir

engleski

External Magnetic Field Density of Main Traction Transformer for EMU

In this paper magnetic flux density in the surrounding of the EMU transformer is modeled and calculated in FEM. Most frequent operating mode for the basic 50 Hz current hamonic and most represented higher harmonic of 1950 Hz loading current are analized. Paper shows loading of the motor windings mode where the magnetic field is maximal. Matching calculated and measured values were obtained on the finished transformer. The developed calculation has proved to be useful tool for the calculation for this type of transformer.

traction transformer; multiwinding transformer; external magnetic field; FEM transformer modelling

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

348-353.

2010.

objavljeno

Podaci o matičnoj publikaciji

Advanced Research Workshop on transformers ARWtr 2010

Lopez-Fernandez, Xose M.

Vigo: University of Vigo

978-84-614-3528-9

Podaci o skupu

The 3rd International Advanced Research Workshop on transformers ARWtr 2010

poster

03.10.2010-06.10.2010

Santiago de Compostela, Španjolska

Povezanost rada

Elektrotehnika