Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Use of small diameter column particles to enhance HPLC determination of histamine and other biogenic amines in seafood (CROSBI ID 165371)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Šimat, Vida ; Dalgaard, Paw Use of small diameter column particles to enhance HPLC determination of histamine and other biogenic amines in seafood // Lebensmittel-Wissenschaft + Technologie = Food science and technology, 44 (2011), 2; 399-406. doi: 10.1016/j.lwt.2010.08.011

Podaci o odgovornosti

Šimat, Vida ; Dalgaard, Paw

engleski

Use of small diameter column particles to enhance HPLC determination of histamine and other biogenic amines in seafood

Pre-column and post-column HPLC derivatization methods were modified and evaluated for the identification and quantification of nine biogenic amines in seafood. Two HPLC methods with column particles of 1.8 µm or 3 µm in diameter were modified and compared to classical methods using 5 µm column particles. Both pre-column derivatization with dansyl chloride and post-column derivatization with O-phthalaldehyde were studied. The HPLC methods were compared with respect to the time of elution, eluent consumption, back-pressure as well as separation, sensitivity, recovery and repeatability for determination of biogenic amines in lean canned tuna and fatty frozen herring. The modified methods using smaller column particles of 1.8 µm or 3 µm allowed biogenic amines to be separated and quantified faster (23-59%) and with less eluent consumption (59-62%) than classical HPLC methods. Back-pressures were below 170 bar and this allowed the use of classical HPLC systems rather than dedicated and costly ultra-high-pressure liquid chromatography (UHPLC) equipment. Biogenic amine separation, sensitivity, recovery and repeatability for the modified methods were similar to or performed better than for the classical HPLC methods. Due to reduced analyses time and eluent consumption the HPLC methods would improve biogenic amine analysis.

histamine; biogenic amines; HPLC columns with small particle-size

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

44 (2)

2011.

399-406

objavljeno

0023-6438

10.1016/j.lwt.2010.08.011

Povezanost rada

Biotehnologija

Poveznice
Indeksiranost