Anodic stripping voltammetry in the complexation study of the peptide Lys-Cys-Thr-Cys-Cys-Ala (56-61)MT I and cadmium: application in determination of complexing capacity and stability constant


Erk, Marijana; Raspor, Biserka
Anodic stripping voltammetry in the complexation study of the peptide Lys-Cys-Thr-Cys-Cys-Ala (56-61)MT I and cadmium: application in determination of complexing capacity and stability constant // Journal of Electroanalytical Chemistry, 502 (2001), 1-2; 174-179 (međunarodna recenzija, članak, znanstveni)


Naslov
Anodic stripping voltammetry in the complexation study of the peptide Lys-Cys-Thr-Cys-Cys-Ala (56-61)MT I and cadmium: application in determination of complexing capacity and stability constant

Autori
Erk, Marijana ; Raspor, Biserka

Izvornik
Journal of Electroanalytical Chemistry (0022-0728) 502 (2001), 1-2; 174-179

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Metallothionein fragment; cadmium; complexation; differential pulse anodic stripping voltammery

Sažetak
A study of Cd complexation with the peptide Lys-Cys-Thr-Cys-Cys-Ala thionein fragment [56-61] MT I (FT) was performed in the differential pulse anodic stripping voltammetric (DPASV) mode. Amperometric titrations of FT with cadmium standard solution were performed in 0.59 mol dm^ -3 NaCl at pH 7.9, and at a constant temperature of 25.0 °C. The signal of FT without cadmium has the peak potential at Ep(FT) = -0.52 V (vs. an Ag/AgCl electrode). As the titration with CdCl_2 proceeds a signal related to CdFT complex appears at the potential Ep(CdFT) = -0.67 V. When the available complexing sites on FT are saturated the signal of Cd ionic appears. From the amperometric titration data the capacity of FT to complex Cd (C_L) and the apparent stability constant of the CdFT complex (K') using modified van den Berg-Ružić-Lee method were determined. Mean value of the stability constant corrected for the partition of the hydrated Cd^2+ ion within the ionic cadmium concentration is 5.3x10^10 dm^3 mol^-1. In addition the titration of the constant Cd^2+ concentration with FT was performed. Due to the excess of cadmium over the FT and vice versa the existence of the complexes of different stoichiometry are proposed causing the poorly resolved signal.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekt / tema
00981511

Ustanove
Institut "Ruđer Bošković", Zagreb

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • SCI-EXP, SSCI i/ili A&HCI