Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Improving the response of copper(II) selective PVC membrane electrode by modification of N2S2 donor ligand (CROSBI ID 164019)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Brinić, Slobodan ; Buzuk, Marijo ; Generalić, Eni ; Bralić, Marija Improving the response of copper(II) selective PVC membrane electrode by modification of N2S2 donor ligand // Acta chimica slovenica, 57 (2010), 318-324

Podaci o odgovornosti

Brinić, Slobodan ; Buzuk, Marijo ; Generalić, Eni ; Bralić, Marija

engleski

Improving the response of copper(II) selective PVC membrane electrode by modification of N2S2 donor ligand

S, S' bis(2 aminophenyl)ethanebis(thioate), (APhET), is reported as N2S2 ligand which form chelate with copper of high stability as compared to the other metals. Two modification of APhET, simpler 1, 2 di-(o-aminophenylthio)ethane (DAPhTE), and the complex one 1, 2-di-(o-salicylaldiminophenylthio)ethane (SAPhTE), were examined as the active material for copper(II) ion selective PVC membrane electrodes, and observed results are correlated. The obtained results with DAPhTE based electrodes show that only coordination abilities of ligand are insufficient for preparing the efficient membrane material. On the other hand, the results that are achieved with electrodes based on SAPhTE actuate interaction of ligand with polymer membrane matrix and necessity of ionophore immobilization in membrane. Optimized SAPhTE based membrane electrode has a linear range down to 10-6 molL 1, with slope of 27.0 mV per decade, very rapid response time (under 5 seconds) and detection limit of 5.1×10 7 molL 1. Such electrode is suitable for determination of copper(II) in analytical measurements by direct potentiometry and in potentiometric titrations, within pH between 2 and 7. The electrode is selective for copper(II) ions over a large number of metal ions, with the exception on Hg2+ ion when is present in concentrations above 2×10 5 molL-1.

copper(II); PVC membrane; selective electrode; ionophore; 1; 2 di (o aminophenylthio)ethane; 1; 2 di (o salicylaldiminophenylthio)ethane

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

57

2010.

318-324

objavljeno

1318-0207

Povezanost rada

Kemija

Indeksiranost