Monitoring of heavy metal ions removal in horizontal rotating tubular bioreactor by TLC (CROSBI ID 561828)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | domaća recenzija

Zelenić, Marina ; Rezić, Iva ; Rezić, Tonči ; Šantek, Božidar Monitoring of heavy metal ions removal in horizontal rotating tubular bioreactor by TLC // VIII. skup mladih kemijskih inženjera, Knjiga sažetaka / Bolf, Nenad ; Šoljić Jerbić, Ivana (ur.). Zagreb: Fakultetu kemijskog inženjerstva i tehnologije, Sveučilišta u Zagrebu, 2010. str. 54-54

Podaci o odgovornosti

Zelenić, Marina ; Rezić, Iva ; Rezić, Tonči ; Šantek, Božidar

engleski

Monitoring of heavy metal ions removal in horizontal rotating tubular bioreactor by TLC

Pollution by heavy metals is a major environmental problem because they are not subject to natural degradation and therefore it comes to their bioaccumulation in tissues, what can cause serious health problems. Generally used bioreactors for metal removal from waste water include rotating biodisc reactors, trickle filters, fixed bed and fluidized beds, air- lift reactors and other biofilm reactors [1]. In this research, removal of metal (Co, Cr and Mn) by biosorption process in horizontal rotating tubular bioreactor (HRTB), was monitored. HRTB is designed as a combination of thin-layer and biodisc reactor and therefore has characteristics of both reactors. Discs are used as carriers for microbial biomass, which removes metals present in water. Biosorption can be defined as the removal of metal or metalloid species, compounds and particles from solution by biological material [2] and it was monitored by thin-layer chromatography. Before analysis of waste water samples, it was necessary to determine the optimal chromatographic system for separating metal ions. In optimization procedure, binary, ternary and quaternary solvent systems with different volume shares were used. Total mixture volume was 10 mL. Therefore, standard solutions of metal salts in distilled water were prepared in range of 0.1-1.0 g/L. These solutions were used for optimization and metal ion identification during real-sample analysis. Based on the obtained chromatograms, calculated retention factors (RF values) and plate development time, the adequate chromatographic system for separation and identification of analysed metal ions was chosen.

horizontal rotating tubular bioreactor; monitoring; heavy metal ions; removal; thin layer chromatography

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

54-54.

2010.

objavljeno

Podaci o matičnoj publikaciji

VIII. skup mladih kemijskih inženjera, Knjiga sažetaka

Bolf, Nenad ; Šoljić Jerbić, Ivana

Zagreb: Fakultetu kemijskog inženjerstva i tehnologije, Sveučilišta u Zagrebu

978-953-6470-48-8

Podaci o skupu

VIII skup mladih kemijskih inženjera

poster

18.02.2010-19.02.2010

Zagreb, Hrvatska

Povezanost rada

Biotehnologija