Stray losses due to inter-bar currents of skewed cage induction motors at no-load (CROSBI ID 87895)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Štefanko, Stjepan ; Slemnik, Bojan ; Zagradišnik, Ivan Stray losses due to inter-bar currents of skewed cage induction motors at no-load // Electrical engineering, 82 (2000), 5; 257-262-x

Podaci o odgovornosti

Štefanko, Stjepan ; Slemnik, Bojan ; Zagradišnik, Ivan

engleski

Stray losses due to inter-bar currents of skewed cage induction motors at no-load

In accordance with present-day efforts to reduce power losses in electrical machines, an analytical approach to estimate the influence of contact resistances between the skewed rotor cage and its laminated iron core on the amount of stray losses of induction motors is made in this paper. Equations for calculation of resistances of the rotor iron core, with which the stray losses due to inter-bar currents are taken into account, are present.

induction motor; stray losses; inter-bar currents