Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Analysis of Different Containment Models for IRIS Small Break LOCA, using GOTHIC and RELAP5 Codes (CROSBI ID 561071)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Papini, Davide ; Cammi, Antonio ; Ricotti, Marco ; Grgić, Davor Analysis of Different Containment Models for IRIS Small Break LOCA, using GOTHIC and RELAP5 Codes // Proceedings of the International Conference Nuclear Energy for New Europe 2009 / Cizelj, Leon ; Končar, Boštjan ; Leskovar, Matjaž (ur.). Ljubljana: Nuclear Society of Slovenia, 2009. str. 714.1-714.10

Podaci o odgovornosti

Papini, Davide ; Cammi, Antonio ; Ricotti, Marco ; Grgić, Davor

engleski

Analysis of Different Containment Models for IRIS Small Break LOCA, using GOTHIC and RELAP5 Codes

Advanced nuclear water reactors rely on containment behaviour in realization of some of their passive safety functions. Steam condensation on containment walls, where non-condensable gas effects are significant, is an important feature of the new passive containment concepts, like the AP600/1000 ones. In this work IRIS reactor was taken as reference, and the relevant condensation phenomena involved within its containment were investigated with different computational tools. In particular, IRIS containment response to a Small Break LOCA (SBLOCA) was calculated with GOTHIC and RELAP5 codes. IRIS containment drywell was modelled with RELAP5 according to a sliced approach, based on the two-pipe-with-junction concept, while it was simulated with GOTHIC testing several modelling options, regarding both heat transfer correlations and volume and thermal structure nodalization. The influence on containment behaviour prediction was investigated in terms of drywell temperature and pressure response, Heat Transfer Coefficient (HTC) and steam volume fraction distribution, and internal recirculating mass flowrate. The objective of the paper is to compare the capability of the two codes in modelling of the same postulated accident, thus to check the results obtained with RELAP5, when applied in a situation not covered by its validation matrix. The option to include or not droplets in fluid mass flow discharged to the containment was the most influencing parameter for GOTHIC simulations. Despite some drawbacks, due e.g. to a marked overestimation of internal natural recirculation, RELAP5 confirmed its capability to satisfactorily model the IRIS containment.

IRIS; Small Break LOCA; GOTHIC; RELAP5

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

714.1-714.10.

2009.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the International Conference Nuclear Energy for New Europe 2009

Cizelj, Leon ; Končar, Boštjan ; Leskovar, Matjaž

Ljubljana: Nuclear Society of Slovenia

978-961-6207-30-0

Podaci o skupu

International Conference Nuclear Energy for New Europe 2009

predavanje

14.09.2009-17.09.2009

Bled, Slovenija

Povezanost rada

Elektrotehnika